articles
Flexible Methods for Microfluidics Devices for handling nanoliter quantities of fluids are creating new fabrication challenges and finding new applications in biology, chemistry, and materials science.
Biotechnology is increasingly about large numbers of experiments, such as analyses of DNA or of drugs, screening of patients, and combinatorial syntheses. All of these procedures require handling fluids. As the number of experiments has grown, the devices used to carry them out have shrunk, and the strategy of "smaller is better" has begun to transform the world of fluidics as it has transformed the world of electronics. The need in biotechnology applications to manipulate fluids moving in small channels--a process called microfluidics--has stimulated three new areas of research: development of new methods for fabricating fluidic systems, invention of components from which to assemble functionally complex fluidic devices, and examination of the fundamental behavior of fluids in small channels.1 Developments in microfluidic technology are also contributing to new experiments in fundamental biology, materials science, and physical chemistry. Interest in microfluidics has been largely motivated by applications, and dimensions and fluids are dictated by these applications. The most mature microfluidic technology is ink-jet printing, which uses orifices less than 100 µm in diameter for the generation of drops of ink. Ink-jet printing is rapidly finding a place in biotechnology for the delivery of reagents to microscopic reactors and for the deposition of DNA into arrays on the surface of biochips. Capillary electrophoresis--a widely used technique for separating different chemical species in aqueous solutions of biological samples--manipulates samples in capillaries that are typically 50 µm in inner diameter. Hand-held systems developed by I-Stat Corp for hospital-based analysis of serum electrolytes were the first commercially developed small analytical systems, and use submillimeter-sized channels. The complex devices now being developed for biological applications--with the analysis of DNA (for genetics and genomics) and proteins (proteomics), and biodefense being the most important--typically involve aqueous solutions and 50- to 100-µm channels. A number of companies are now pursuing the commercialization of microfluidic devices. Unlike microelectronics, in which the current emphasis is on reducing the size of transistors, microfluidics is focusing on making more complex systems of channels with more sophisticated fluid-handling capabilities, rather than reducing the size of the channels. These systems require the same types of components as larger fluid-handling systems: pumps, valves, mixers, filters, separators, and the like. Although the sizes of channels are large relative to the size of features in microelectronic devices, they are small enough so that flows in them behave quite differently than do the large-scale flows that are familiar from everyday life. The components needed at small scales are therefore often quite different from those used at large scales. To design the components required for complex microfluidic systems, it is first necessary to understand the properties of fluids flowing in small channels. Fortunately, new, flexible methods of fabricating microchannels, combined with imaging techniques such as confocal microscopy that make it possible to quantify flows in these channels, allow the physics of microflows to be examined at previously unattainable resolution.
Flows in microchannels
Laminar flow is the definitive characteristic of microfluidics. Fluids flowing in channels with dimensions on the order of 50 µm and at readily achievable flow speeds are characterized by low Reynolds number, Re. As described in box 2, flows in this regime are laminar, not turbulent: The surfaces of constant flow speed are smooth over the typical dimension of the system, and random fluctuations of the flow in time are absent. In the long, narrow geometries of microchannels, flows are also predominantly uniaxial: The entire fluid moves parallel to the local orientation of the walls. The significance of uniaxial laminar flow is that all transport of momentum, mass, and heat in the direction normal to the flow is left to molecular mechanisms: molecular viscosity, molecular diffusivity, and thermal conductivity.
Electrically driven flow, known as electroosmosis, offers a useful alternative to pressure-driven flow of water, but has its own weaknesses: sensitivity to impurities that adsorb on the wall of the channel, ohmic generation of heat in the fluid, and the need for high voltages (on the order of kilovolts). In electroosmosis, illustrated in Figure 1b, an electric field generates a net force on the fluid near the interface of the fluid with its solid boundaries, where a small separation of charge occurs due to the equilibrium adsorption and desorption of ions. For water in contact with silica, the ionization of silanol groups (Si-OH In the laminar flows generated by these pumping schemes, adjacent streams of fluids with different chemical composition remain distinct except for diffusive mixing at their interface. We have studied this diffusion process in Poiseuille flows using fluorescence confocal microscopy. The confocal microscope allows us to visualize the 3D shape of the diffusively mixed region between streams of solutions that contain molecules that become fluorescent when they react with one another. We found that the width of the intermixed region grows as (Dτ)1/2 near the center of the channel, where the flow speed is almost uniform, and as (Dτ)1/3 near the top and bottom walls, where the flow speed is changing rapidly as a function of the distance from the wall. Here, D is the molecular diffusivity and τ is the time that the two streams have been in contact. These results agree with dimensional scaling arguments that extend the classic result in transport theory, known as the Lévêque problem, for diffusion perpendicular to the walls.4
Another pumping scheme that involves patterning the properties of the walls of a microchannel uses surface tension to move drops of a fluid surrounded by air. Spatial variations in the temperature of the walls of the channel create gradients in the tension of the liquid-vapor interface of the drop: The surface tension decreases as the temperature increases. By building resistive heating elements into the microchannel wall, the group of Mark Burns at the University of Michigan can move drops of fluid in a channel by heating the wall near the rear of the drop. The decrease in the surface tension from the front to the back of the drop pulls the drop through the channel. The advantage of moving independent drops of solution in microchannels is that the contents of each drop may be kept separate from that of neighboring drops.6 (See also Physics Today, January 2000, page 9*.)
Microfluidic components
Pumps, valves, and mixers are some of the basic building blocks of any integrated microfluidic system. There is still no broad agreement on the best designs for these components or even on the materials to be used for their construction; the technology is still a work in progress. Ultimately, most bioanalytical systems will probably be made of polymers because these materials are inexpensive. Applications involving organic solvents or high temperatures may require glass.
Figure 3b shows a mixer designed by David Beebe's group at the University of Wisconsin (formerly at the University of Illinois) and illustrates the types of new devices that must be developed to perform familiar functions when turbulence is no longer available as an aid. This 3D serpentine channel acts as a passive mixer for laminarly flowing fluids based on a type of chaotic flow known as chaotic advection. Chaotic advection appears in certain steady 3D flows and time-dependent 2D flows, and mixes the fluid by continuously stretching different volumes of the fluid and folding them into one another. In a qualitative sense, the path taken by a given fluid element in the flow depends in a sensitive way on its encounters with a series of weak secondary flows or eddies, present even at low Re in the corners of channels, that transport the element across the flow.7
Microfluidics in the laboratory
A second problem of broad interest in cell biology is that of observing the behavior of cells in gradients (see Physics Today, January 2000, page 24*). How does a cell sense the gradient and how does it respond to it? The network of channels in Figure 5b forms gradients in the concentration of molecules present in a stream of buffer. The strategy is to start with a small number of fluid streams and then to allow them to divide and mix into multiple streams carrying the gradient. Recombination of these multiple streams into a single stream, under conditions of laminar flow, allows the gradient to be propagated along the length of the larger channel with only diffusional broadening of the gradient profile. In the microfluidic system shown, a linear gradient from red to green with three gradations is transformed into a linear gradient with nine gradations. The horizontal channels with serpentine profile allow the two streams flowing laminarly through them to mix their composition completely by diffusion. The serpentine form keeps the device compact; it does not influence mixing (unlike the chaotic advection mixer of Figure 3b). By changing the number of input channels and the order in which the different initial solutions are injected, one can generate a variety of smooth gradients over relatively broad channels (up to millimeters) with a limited number of initial solutions.10 A third problem that can be addressed using laminar flows in microchannels is the measurement of the kinetics of chemical reactions that are initiated by mixing two or more components. The strategy used is to inject the reaction component solutions into adjacent streams flowing laminarly in a single channel. At the interface between the streams, the components mix by diffusion, which initiates the reaction. For steady injection of solutions of constant composition, the flow, the degree of mixing, and the state of reaction reach a steady state in the stationary frame of the laboratory; observing the state of the reaction at different distances downstream from the point of injection allows the temporal evolution of the reaction to be monitored. Figure 5c shows how controlled mixing between adjacent laminar flows has been used to study the early stages of protein folding. An advantage of this method is that the width of the mixing volume can be reduced, by hydrodynamic focusing, to lower the mixing time (which scales as the square of the width of the mixing volume). The experiments achieved submillisecond resolution for the measurement of the initial collapse of the protein.11 (See also Physics Today, June 1998, page 9*.)
What's downstream
What's next for microfluidics? Perhaps nanofluidics; perhaps unusual fluids; certainly applications. Some work on nanometer-scale fluidic systems has already begun. The group of Harold Craighead at Cornell University has demonstrated that high-molecular-weight DNA can be separated by electrophoresis in the absence of a gel in a microchannel about 50 µm wide and 10 cm long with a depth that alternates between 0.1 and 1 µm along its length. The thick sections of the channel retard the progress of small fragments more than large fragments. This trend is the opposite of what happens in standard gel electrophoresis, in which the small fragments travel more quickly than the larger ones. Transport phenomena in nanoscopic channels are not well understood. Work in porous materials, theory, and simulations all suggest that qualitatively new behavior--such as slip at the liquid-solid interface or inhomogeneity of transport coefficients--will emerge as the size of channels shrinks.12 There will be ways to exploit these phenomena in the design of new fluidic components. The use of non-Newtonian fluids, for which the viscosity depends on the shear rate, is another promising direction for the development of microfluidics devices. Colloidal suspensions and concentrated polymer solutions, which include many biological fluids, are common examples of non-Newtonian fluids. In such fluids, the viscosity either grows (shear thickening) or decreases (shear thinning) with increasing shear rate. There are examples of turbulentlike instabilities in flows of non-Newtonian fluids at low Reynolds number. These instabilities, named "elastic turbulence," could perhaps be generated in microfluidic channels to act as efficient mixers.13 While microfluidic devices are beginning to be commercialized, there is still no standard for even the simplest components such as pumps, valves, and mixers; the field remains open for exploration. This exploration is facilitated by the move toward simple fabrication methods--rapid prototyping based on the molding of elastomers--that reduce costs and delays. These methods also allow the mechanical properties of the flexible substrate to play a role in the function of the device. Current microfluidic devices are usually attached to a thoroughly macroscopic box that contains power supplies, optical elements, and fluidic interfaces for the introduction and extraction of samples. An open challenge is the chip-scale integration of multiple fluidic components with electrical and optical controls into fully functional devices. There also remains plenty of room for the invention of new applications of microfluidics, both in and out of the laboratory. Imagine a T-shirt made from a fabric of microchannels, carrying coolants and monitoring vital signs, and entirely powered by the body heat of the wearer. It's not impossible! We are grateful to Howard Stone (Division of Applied Science and Engineering, Harvard University) for helpful suggestions. Work in our laboratory on microfluidics is supported by DARPA: NSF ECS-9729405, NIH: GM51559, and NSF: DMR-9809363 MRSEC. A.D.S. was supported by NIH Molecular Biophysics Training Grant No. 5T32GM08313-10.
1. See the articles in the proceedings of the Micro Total Analysis Symposia, including Micro Total Analysis Systems, A. van den Berg, P. Bergveld, eds., Kluwer, Dortrecht, the Netherlands (1994); Micro Total Analysis Systems '98, D. J. Harrison, A. van den Berg, eds., Kluwer, Dortrecht (1998); Micro Total Analysis Systems 2000, A. van den Berg, W. Olthuis, P. Bergveld, eds., Kluwer, Dortrecht (2000).
2. G. T. A. Kovacs, Micromachined Transducers Sourcebook, WCB, Boston (1998). A. Manz et al., Chimia 45, 103 (1991). D. J. Harrison et al., Science 261, 895 (1993).
3. P. H. Paul, M. G. Garguilo, D. J. Rakestraw, Anal. Chem. 70, 2459 (1998).
4. R. B. Bird, Transport Phenomena, Wiley, New York (1960). R. F. Ismagilov et al., Appl. Phys. Lett. 76, 2376 (2000).
5. A. D. Stroock et al., Phys. Rev. Lett. 84, 3314 (2000).
6. M. A. Burns et al., Proc. Natl. Acad. Sci. USA 93, 5556 (1996).
7. R. H. Liu et al., J. Microelectromech. Syst. 9, 190 (2000). J. M. Ottino, The Kinetics of Mixing: Stretching, Chaos, and Transport, Cambridge U. Press, Cambridge (1989).
8. M. A. Unger et al., Science 288, 113 (2000).
9. S. Takayama et al., Proc. Natl. Acad. Sci. USA 96, 5545 (1999).
10. N. L. Jeon et al., Langmuir 16, 8311 (2000).
11. L. Pollack et al., Proc. Natl. Acad. Sci. USA 96, 10115 (1999).
12. R. Pit, H. Hervet, L. Leger, Phys. Rev. Lett. 85, 980 (2000). J.-L. Barrat, L. Bocquet, Phys. Rev. Lett. 82, 4671 (1999).
13. A. Groisman, V. Steinberg, Nature 410, 905 (2001).
14. J. C. McDonald et al., Electrophoresis 21, 27 (2000).
15. S. R. Quake, A. Scherer, Science 290, 1536 (2000). D. J. Beebe et al., Proc. Natl. Acad. Sci. USA 97, 13488 (2000).
16. J. P. Brody et al., Biophys. J. 71, 3430 (1996). S. Vogel, Life in Moving Fluids: The Physical Biology of Flow, Princeton U. Press, Princeton, New Jersey (1994).
January 2000, page 9
January 2000, page 24 June 1998, page 9
|
|
|